Comparison of Methods

Measurement Duration
Sufficiently long to be representative of sound of all tasks performed.
Position of Microphone
Mid-top of shoulder
Measurement Duration
Sufficiently long to be representative of sound of each task performed.
Position of Microphone
In hearing zone of worker

Dosimetry

Profiling

Previous slide Next slide Back to first slide View graphic version

Notes:

In comparing the measurement procedures of dosimetry and profiling, the major differences are in the measurement duration and the position of the microphone.
In dosimetry, S12.19 says that the measurement duration should be sufficiently long for the resulting noise exposure to be representative of the exposure associated with all the tasks performed by the employee.
In profiling which normally uses an integrating sound level meter, the duration should be sufficiently long for the resulting noise exposure to be representative of the exposure associated with each tasks performed by the employee.
In dosimetry, the position of the microphone is on the mid-top of the wearer's shoulder with the microphone oriented parallel to the shoulder plane. While the procedure in profiling would locate the microphone in what is called the hearing zone of the worker, (a hemispheric area extending from the workers ear to a distance of 12 inches) and allows for alternate positions when the worker's activities may interfere with the measurement. It also allows for measurements to be taken even if the worker is not present.